Skip to main content
NextLink USA

The physical layer everything else depends on.

Telecom services

Full RF deployment, site acquisition and 24/7 NOC operations — with the surveys, tower works, transmission and earthing underneath, built and commissioned to standard.

Almost every network fault that takes days to find turns out to be physical: a corroded connector, an earth that was never bonded, a mast that moved, a feeder with water in it. The physical layer is the cheapest thing to get right at build and the most expensive to fix later.

We acquire, build, commission and operate telecom infrastructure — site acquisition, RF deployment, towers and masts, transmission links, telecom power and earthing — hand over the sweep traces and earth readings that prove it was done properly, and keep it running from a 24/7 network operations centre.

  • Structural work done to a code

    Tower and mast installations designed and inspected against TIA-222, with loading assessed before anything new is mounted rather than after the structure starts to flex.

  • Earthing that is measured, not assumed

    Earth electrode resistance measured and recorded, bonding verified to IEEE 1100 practice, and surge protection coordinated through the whole path rather than bolted on at one end.

  • Antenna systems swept and documented

    Return loss and distance-to-fault sweeps on every feeder at handover, filed as the baseline that future fault-finding gets compared against.

  • Operated around the clock

    24/7 NOC monitoring of the sites we build and the networks we take over, with alarms triaged and faults dispatched before they turn into outages.

Capabilities

Scope of work

RF deployment and operations

Site acquisition
Candidate site search, lease and permitting support through to a buildable site
RF deployment
RF design, installation, integration, drive testing and optimisation from first site to full rollout
NOC operations
24/7 network operations centre monitoring, alarm handling and fault dispatch

Survey and assessment

Site surveys
Physical, RF and power surveys with measured, recorded conditions
Structural assessment
Loading review against TIA-222 before additional mounts are approved
Coverage and path
RF coverage prediction and microwave path profiling with clearance analysis
Condition audits
Existing-site audits with photographic records and a prioritised defect list

Installation

Structures
Monopole, lattice, rooftop and wall-mounted installations
Antenna systems
Panel, microwave and omnidirectional mounting, alignment and weatherproofing
Feeders
Coaxial and hybrid feeder routing, grounding kits, sweep testing
Equipment
Cabinet and shelter fit-out, rack build, cable management and labelling
Earthing
Electrode systems, bonding networks and coordinated surge protection

Transmission

Microwave
Licensed and unlicensed links, alignment, capacity and availability verification
Fiber backhaul
Terminations, patching and end-to-end optical budget verification
Synchronisation
Timing distribution and verification where the network requires it

Power and environment

Telecom DC
−48 VDC rectifier plant, distribution and battery installation
Standby
Generator and transfer-switch interfacing, alarm integration
Environmental
Cooling, ventilation and temperature alarm installation
Monitoring
Alarm points mapped to the operator's existing NOC platform

Figures on these pages describe what we routinely deliver. Anything specific to your site is confirmed from a survey before it is priced.

Standards we work to

  • TIA-222

    Structural standard for antenna supporting structures

  • ANSI/TIA-568

    Commercial building telecommunications cabling

  • ANSI/TIA-607

    Bonding and grounding for telecommunications

  • IEEE 1100

    Powering and grounding electronic equipment

  • IEEE 81

    Measuring earth resistivity and ground impedance

  • NFPA 70 (NEC)

    Electrical installation requirements

  • IEC 60529

    Degrees of protection provided by enclosures

  • IEC 62305

    Protection against lightning

Typical applications

  • Full RF deployment, from site acquisition to optimisation
  • 24/7 NOC monitoring and fault management
  • Greenfield and co-location cell site build
  • Microwave backhaul links and ring closure
  • Rooftop and in-building telecom infrastructure
  • Substation and plant telecom rooms
  • Remote site power, earthing and environmental works
  • Site audits and defect remediation programmes

What you receive

  • Survey report with measured site conditions and photographs
  • Structural loading assessment where new mounts are added
  • Installation drawings, cable schedules and labelling schedule
  • Feeder sweep traces and antenna alignment records
  • Earth resistance readings and bonding verification records
  • Commissioning and site acceptance test records, countersigned
  • As-built documentation and recommended spares list

Where we do it

  • Power & utilities

    Protection, control, SCADA communications and DC power for grids and substations.

  • Oil & gas

    Hazardous-area communications and DC power for plants, terminals and offshore.

  • Government authorities

    Mission-critical radio, secure networks and standby power for public agencies.

  • Transportation

    Operational radio, corridor networks and passenger communications for transport.

Frequently asked questions

Before you send an enquiry

Can you work on a live site?

Usually, yes. Most of our work on operational networks happens under permit with agreed isolation and a rollback plan written before mobilisation. Where a change genuinely cannot be made live we will say so at proposal stage rather than discover it on the night.

Do you do the structural work as well as the electronics?

We carry out mounting, feeder and antenna works and will assess loading against TIA-222 before adding to a structure. Structural strengthening or foundation design is referred to a qualified structural engineer — we will tell you when that point is reached rather than take a view on it ourselves.

What do you hand over at the end?

Sweep traces for every feeder, earth resistance readings, alignment records, as-built drawings, a labelling schedule and the commissioning test sheets, countersigned on site. That package is what makes the next fault a half-day job instead of a week.

Next step

Let’s build a connected tomorrow.

Contact our engineering team to design, upgrade or manage your critical telecom infrastructure. Send a scope, a drawing or just the problem, and we will come back with an approach and a priced proposal.