Safety and connectivity where the nearest road is a helicopter ride away.
Off-shore comms
ATEX-certified maritime VSAT, LTE and rig safety PAGA — with the explosion-proof CCTV and emergency systems an offshore installation is certified against.
An offshore installation depends on its communications for two things that cannot wait: running the operation and getting people to safety. Both have to work in a classified area, in salt and vibration, on a link that weather and distance try to take away.
We deliver the communications an offshore operator owns — high-throughput VSAT, LTE and microwave links to shore, and the ATEX and IECEx certified PAGA, CCTV and safety systems on board — installed and inspected to the hazardous-area codes.
Maritime and rig VSAT / LTE
High-throughput satellite and microwave links for offshore platforms, with offshore LTE where coverage allows, and failover between them defined rather than improvised.
Explosion-proof hardware
ATEX and IECEx certified safety systems, CCTV and emergency PAGA, with protection concept, gas group and temperature class recorded per device.
PAGA that is heard over the plant
Speaker layouts modelled against measured machinery noise and verified for speech intelligibility at commissioning, so an alarm is understood, not just loud.
Built for the marine environment
316 stainless, GRP and marine-grade materials, ingress protection and vibration-tolerant mounting chosen for the deck, not the datasheet.
Capabilities
Scope of work
Connectivity
- VSAT
- Stabilised maritime and fixed rig terminals, high-throughput satellite service integration
- LTE
- Offshore LTE and private LTE where coverage and licensing allow
- Microwave
- Platform-to-platform and platform-to-shore links with path and availability analysis
- Failover
- Defined priority and failover between fiber, microwave, LTE and satellite paths
Safety systems
- PAGA
- Public address and general alarm with redundant A/B amplification and supervision
- CCTV
- Explosion-proof cameras for process, deck and perimeter monitoring
- Emergency communications
- Alarm tones, muster messaging and interfaces to fire and gas and ESD
- Radio
- Onboard UHF/VHF and marine radio integration
Hazardous area
- Certification
- ATEX and IECEx certified equipment for Zone 1 and Zone 2
- Installation
- Installation and inspection to IEC 60079-14 by competent personnel
- Materials
- 316 stainless, GRP and copper-free aluminium; IP66 and above
Figures on these pages describe what we routinely deliver. Anything specific to your site is confirmed from a survey before it is priced.
Standards we work to
IEC 60079 series
Explosive atmospheres — equipment and installation
ATEX 2014/34/EU
Equipment for potentially explosive atmospheres
IECEx
Certification scheme for equipment in explosive atmospheres
IEC 61892
Mobile and fixed offshore units — electrical installations
IEC 60268-16
Objective rating of speech intelligibility by speech transmission index
IEC 60945
Maritime navigation and radiocommunication equipment — environmental requirements
Typical applications
- Fixed platform and rig communications
- FPSO and vessel VSAT connectivity
- Platform PAGA and emergency alarm systems
- Explosion-proof CCTV for process and deck areas
- Offshore LTE and microwave links to shore
- Communications upgrades during planned shutdowns
What you receive
- Link budget and availability calculation for each path
- PAGA speaker layout and intelligibility calculation
- Hazardous-area certificate pack, per device type
- Installation drawings and cable schedules
- Commissioning records, including measured intelligibility
- Failover test records across connectivity paths
- Operations documentation and operator training
Where we do it
Oil & gas
Hazardous-area communications and DC power for plants, terminals and offshore.
Power & utilities
Protection, control, SCADA communications and DC power for grids and substations.
Transportation
Operational radio, corridor networks and passenger communications for transport.
Frequently asked questions
Before you send an enquiry
Satellite, LTE or fiber?
Usually more than one. Fiber where a submarine cable is available, microwave or LTE where the distance allows, and VSAT as the path that always reaches. We design the priority and failover between them so the operation knows which services keep running when a path drops.
Is your equipment certified for the zone?
Yes. Field equipment is ATEX and IECEx certified for the area classification it is installed in, and the submittal records protection concept, gas group, temperature class and certificate number per device type.
Can the work be done during a shutdown window?
Yes, and for most PAGA and safety-system work it has to be. We plan pre-fabrication, testing and spares around the shutdown so the time offshore is spent installing, not waiting.
Next step
Let’s build a connected tomorrow.
Contact our engineering team to design, upgrade or manage your critical telecom infrastructure. Send a scope, a drawing or just the problem, and we will come back with an approach and a priced proposal.