Certified for the area classification, built for the corrosion.

Oil & gas

PA/GA, radio coverage, plant networks and DC power for plants, terminals, pipelines and offshore installations — installed and inspected to the hazardous-area codes.

In a process facility, the communication system is part of the safety case. It has to be audible over a compressor, certified for the zone it sits in, and survive years of salt, sand and hydrogen sulphide without the enclosure giving up first.

We design, install and maintain hazardous-area communications, plant networks and the DC systems behind fire and gas, emergency shutdown and control — with the certification recorded per device rather than per order.

  • Area classification drives everything

    A device that is fine in Zone 2 is not acceptable in Zone 1, and a Division 2 listing does not satisfy a Zone 1 requirement. We record protection concept, gas group and temperature class per item so review is a document check, not an argument.

  • Plant noise defeats ordinary speakers

    A compressor house at 100 dBA needs a design that targets intelligibility, not sound pressure. That means re-entrant horns on a modelled layout and a measured speech transmission index at commissioning.

  • Corrosion is the real service-life limit

    Coastal and sour-service environments eat painted mild steel. 316 stainless, glass-reinforced polyester and copper-free aluminium get specified per location rather than applied uniformly to keep a quotation tidy.

  • Turnarounds are the only maintenance window

    If a device can only be replaced during a shutdown, the spares holding has to anticipate it — built around the turnaround interval and the certification lead time for replacements.

Capabilities

Related services

  • Hazardous-area PA/GA and radio

    Ex d, Ex e and Ex ia loudspeakers, beacons, handsets and call stations for Zone 1, Zone 2, Division 1 and Division 2, with plant-wide radio coverage and control-room dispatch.

    Learn more
  • Plant networks and OT segmentation

    Industrial Ethernet rated for the environment, IEC 62443 zone and conduit segmentation between process and business networks, and the wireless that maintenance teams actually use.

    Learn more
  • DC power for safety systems

    24, 48 and 125 VDC chargers and distribution for fire and gas panels, emergency shutdown, switchgear control and telecom, with earth-fault detection and full alarm mapping.

    Learn more
  • Offshore communications

    Maritime and rig VSAT and LTE, ATEX-certified PAGA and CCTV, and submarine fiber links for platforms and terminals that cannot be reached by road.

    Learn more

How we work here

  • Field devices certified under IEC 60079 for ATEX and IECEx, or listed to the NEC for Class I Division 1 and 2.
  • Installation and inspection to IEC 60079-14 by competent personnel, recorded per device.
  • Certificate number, protection concept, gas group, temperature class and ingress rating stated per device type.
  • Enclosure material selected per location: 316 stainless, GRP or copper-free aluminium.
  • Speech intelligibility designed and verified to IEC 60268-16 against measured ambient noise.
  • Permit-to-work, method statements and risk assessments agreed before mobilisation.

Related services

Frequently asked questions

Before you send an enquiry

Can you work to a client's own engineering standards?

Yes. Major operators work to their own engineering standards and material specifications on top of the international codes. Send the applicable documents with the enquiry and we return a compliance statement against them, flagging anything that cannot be met rather than discovering it at inspection.

What environmental ratings do you work to as standard?

−40 °C to +70 °C operation and NEMA 4X / IP66 as the baseline for outdoor field devices, with material selection driven by location: 316 stainless or GRP for coastal and sour service, copper-free aluminium where weight matters. We state the assumption in the proposal so it can be challenged before the order.

Do you mobilise offshore?

Yes — platforms, FPSOs and marine terminals, subject to the operator's certification, medical and survival requirements for personnel. Tell us the installation type with the enquiry so mobilisation requirements are in the proposal rather than discovered later.

Next step

Let’s build a connected tomorrow.

Contact our engineering team to design, upgrade or manage your critical telecom infrastructure. Send a scope, a drawing or just the problem, and we will come back with an approach and a priced proposal.