Hazardous-area PA/GA and radio
Ex d, Ex e and Ex ia loudspeakers, beacons, handsets and call stations for Zone 1, Zone 2, Division 1 and Division 2, with plant-wide radio coverage and control-room dispatch.
Learn moreCertified for the area classification, built for the corrosion.
PA/GA, radio coverage, plant networks and DC power for plants, terminals, pipelines and offshore installations — installed and inspected to the hazardous-area codes.
In a process facility, the communication system is part of the safety case. It has to be audible over a compressor, certified for the zone it sits in, and survive years of salt, sand and hydrogen sulphide without the enclosure giving up first.
We design, install and maintain hazardous-area communications, plant networks and the DC systems behind fire and gas, emergency shutdown and control — with the certification recorded per device rather than per order.
A device that is fine in Zone 2 is not acceptable in Zone 1, and a Division 2 listing does not satisfy a Zone 1 requirement. We record protection concept, gas group and temperature class per item so review is a document check, not an argument.
A compressor house at 100 dBA needs a design that targets intelligibility, not sound pressure. That means re-entrant horns on a modelled layout and a measured speech transmission index at commissioning.
Coastal and sour-service environments eat painted mild steel. 316 stainless, glass-reinforced polyester and copper-free aluminium get specified per location rather than applied uniformly to keep a quotation tidy.
If a device can only be replaced during a shutdown, the spares holding has to anticipate it — built around the turnaround interval and the certification lead time for replacements.
Capabilities
Ex d, Ex e and Ex ia loudspeakers, beacons, handsets and call stations for Zone 1, Zone 2, Division 1 and Division 2, with plant-wide radio coverage and control-room dispatch.
Learn moreIndustrial Ethernet rated for the environment, IEC 62443 zone and conduit segmentation between process and business networks, and the wireless that maintenance teams actually use.
Learn more24, 48 and 125 VDC chargers and distribution for fire and gas panels, emergency shutdown, switchgear control and telecom, with earth-fault detection and full alarm mapping.
Learn moreMaritime and rig VSAT and LTE, ATEX-certified PAGA and CCTV, and submarine fiber links for platforms and terminals that cannot be reached by road.
Learn moreZero-downtime TETRA and P25 secure voice and data systems.
Scalable LAN/WAN, SD-WAN, DWDM transport and zero-trust cybersecurity.
Industrial AC/DC rectifiers, chargers and EMS battery backup.
ATEX-certified maritime VSAT, LTE and rig safety PAGA.
Subsea cable landing stations, PFE and seabed surveying.
Frequently asked questions
Yes. Major operators work to their own engineering standards and material specifications on top of the international codes. Send the applicable documents with the enquiry and we return a compliance statement against them, flagging anything that cannot be met rather than discovering it at inspection.
−40 °C to +70 °C operation and NEMA 4X / IP66 as the baseline for outdoor field devices, with material selection driven by location: 316 stainless or GRP for coastal and sour service, copper-free aluminium where weight matters. We state the assumption in the proposal so it can be challenged before the order.
Yes — platforms, FPSOs and marine terminals, subject to the operator's certification, medical and survival requirements for personnel. Tell us the installation type with the enquiry so mobilisation requirements are in the proposal rather than discovered later.
Next step
Contact our engineering team to design, upgrade or manage your critical telecom infrastructure. Send a scope, a drawing or just the problem, and we will come back with an approach and a priced proposal.