Messages people can act on, in places that are loud, large or on fire.
Mission-critical communication
Zero-downtime TETRA and P25 secure voice and data systems, plus PA/GA, voice evacuation, dispatch and mass notification — including hazardous-area field devices.
A communication system is only worth what people understand when it is running. Intelligibility, not loudness, moves people to a muster point — which is why the specification that matters is IEC 60268-16, and why coverage is modelled and then measured rather than assumed.
We design, install and commission TETRA and P25 radio, secure voice and data, and voice alarm systems for sites where the message has consequences: plants, terminals, utilities, transport networks and control rooms.
Intelligibility designed, then proven
Coverage modelled to a speech transmission index target before installation, taking plant noise, reverberation and speaker spacing into account, then measured again at commissioning and recorded.
Hazardous area as a first-class case
Zone 1, Zone 2, Class I Division 1 and 2 devices with ATEX and IECEx certification, installed and inspected to IEC 60079-14 by competent personnel, with certificate numbers recorded per device.
Supervised to the last speaker
Line supervision detects open circuit, short circuit and earth fault on every zone, with end-of-line monitoring. A failed branch raises an alarm rather than being discovered during a drill.
Interfaced to what is already there
Fire alarm panels, DCS and ESD, access control, CCTV, PBX and two-way radio. A process event can raise the right message in the right area without an operator in the loop.
Capabilities
Scope of work
Radio systems
- Technologies
- TETRA and P25 as standard; DMR and conventional analogue where the site requires
- Secure voice and data
- Encryption, authentication and short-data services for field teams
- Coverage
- Prediction modelling, drive and walk testing, in-building DAS and bi-directional amplifiers
- Dispatch
- Console positions, talkgroup design, recording and interoperability gateways
- Infrastructure
- Repeaters, combiners, antenna systems and link planning
Public address and general alarm
- Architecture
- IP/SIP over the facility network, 70 V / 100 V constant-voltage line, or hybrid
- Zones
- 2 to 500+, expandable without replacing the head end
- Amplification
- 60 W to 1200 W per zone with N+1 standby and automatic changeover
- Supervision
- Open, short and earth fault; pilot-tone end-of-line monitoring
- Backup power
- Integral charger and battery sized to the project standby and alarm duty
Field devices
- Loudspeakers
- Re-entrant horns 15–60 W, paging projectors, ceiling and wall units
- Visual devices
- LED beacons, xenon strobes and combination sounder/beacons, synchronised per field of view
- Stations
- Weatherproof handsets, noise-cancelling call points, guard and gate stations
- Hazardous area
- Ex d, Ex e and Ex ia; 316 stainless, GRP and copper-free aluminium; NEMA 4X / IP66
Performance and integration
- Intelligibility
- STI ≥ 0.50 (CIS ≥ 0.70) per IEC 60268-16 for emergency messaging
- Sound pressure
- 10–15 dB above measured ambient, referenced to L90, capped at 110 dBA at occupied positions
- Life safety
- Supervised interface to the fire alarm panel, which holds highest message priority
- Process and security
- Modbus TCP, OPC and dry contacts; access control and CCTV event triggers
- Messaging
- Pre-recorded sets for evacuation, shelter-in-place, lockdown, test and all-clear
Figures on these pages describe what we routinely deliver. Anything specific to your site is confirmed from a survey before it is priced.
Standards we work to
NFPA 72
National Fire Alarm and Signaling Code, Chapter 24 — emergency communications
NFPA 1221
Installation and maintenance of emergency services communications systems
UL 2572
Mass notification systems
UL 1480 / UL 1711
Speakers and amplifiers for fire protective signalling
IEC 60268-16
Objective rating of speech intelligibility by speech transmission index
IEC 60849 / ISO 7240-19
Sound systems for emergency purposes
EN 54-16 / EN 54-24
Voice alarm control equipment and loudspeakers
TIA-102
P25 digital land mobile radio
IEC 60079 series
Explosive atmospheres — equipment and installation
Typical applications
- Plant-wide public address and general alarm (PA/GA)
- Evacuation, shelter-in-place and all-clear messaging
- Control room to field talk-back
- Site-wide radio coverage and in-building DAS
- Station, terminal and campus emergency announcement
- Terminal, car park and marine berth communications
- Control room dispatch and interoperability gateways
What you receive
- Zone plan, speaker layout and device schedule
- Predicted sound pressure and speech intelligibility calculation
- Amplifier loading schedule and battery autonomy calculation
- Cable schedule and loop supervision diagram
- Hazardous-area certificate pack, per device type
- Measured intelligibility results recorded at commissioning
- Message schedule with approved scripts, and operator training
Where we do it
Oil & gas
Hazardous-area communications and DC power for plants, terminals and offshore.
Power & utilities
Protection, control, SCADA communications and DC power for grids and substations.
Government authorities
Mission-critical radio, secure networks and standby power for public agencies.
Transportation
Operational radio, corridor networks and passenger communications for transport.
Frequently asked questions
Before you send an enquiry
How do you prove the system will be intelligible?
Coverage is modelled using your room dimensions, surface treatments and measured or estimated ambient noise, targeting a speech transmission index of at least 0.50 for emergency messaging. The model is issued with the design, and the figure is measured again at commissioning so there is a record of the as-built result rather than the intended one.
Can the same system handle evacuation and day-to-day paging?
Usually it should — a system used daily is a system known to work. Routine paging runs at the lowest priority and is pre-empted instantly by fire or lockdown messaging. Where the authority having jurisdiction requires physical separation of the life-safety path, we design that instead and state why.
Do you install Ex-certified devices yourselves?
Yes, with installation and inspection to IEC 60079-14 by competent personnel. The submittal records protection concept, gas group, temperature class, ambient range and certificate number for each device type, which is what an inspector will ask for.
Next step
Let’s build a connected tomorrow.
Contact our engineering team to design, upgrade or manage your critical telecom infrastructure. Send a scope, a drawing or just the problem, and we will come back with an approach and a priced proposal.